Cardiology

Posted November 30th 2020

One-Year Outcomes of Mitral Valve-in-Valve Using the SAPIEN 3 Transcatheter Heart Valve.

Michael J. Mack M.D.

Michael J. Mack M.D.

Whisenant, B., Kapadia, S.R., Eleid, M.F., Kodali, S.K., McCabe, J.M., Krishnaswamy, A., Morse, M., Smalling, R.W., Reisman, M., Mack, M., O’Neill, W.W., Bapat, V.N., Leon, M.B., Rihal, C.S., Makkar, R.R. and Guerrero, M. (2020). “One-Year Outcomes of Mitral Valve-in-Valve Using the SAPIEN 3 Transcatheter Heart Valve.” JAMA Cardiol 5(11): 1245-1252.

Full text of this article.

IMPORTANCE: Bioprosthetic mitral valves are implanted with increasing frequency but inevitably degenerate, leading to heart failure. Reoperation is associated with high morbidity and mortality. Transcatheter mitral valve-in-valve (MViV) using balloon-expandable transcatheter valves has emerged as an alternative for high-surgical risk patients. OBJECTIVE: To assess contemporary outcomes of SAPIEN 3 (Edwards Lifesciences) MViV replacement. DESIGN, SETTING, AND PARTICIPANTS: In this registry-based prospective cohort study of SAPIEN 3 MViV, patients entered in the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry from June 2015 to July 2019 were analyzed. US Centers for Medicare and Medicaid linkage ensured comprehensive collection of death and stroke data. EXPOSURES: Mitral valve-in-valve for degenerated bioprosthetic mitral valves. MAIN OUTCOMES AND MEASURES: The primary efficacy end point was 1-year mortality. The primary safety end point was procedural technical success as defined by the Mitral Valve Academic Research Consortium criteria. Secondary end points included 30-day mortality, New York Heart Association-defined heart failure, and mitral valve performance. RESULTS: A total of 1529 patients (mean [SD] age, 73.3 [11.84] years; 904 women [59.1%]) underwent transseptal or transapical MViV implant at 295 hospitals between June 2015 and July 2019. The mean (SD) Society of Thoracic Surgeons predicted risk of mortality was 11.1% (8.7%). Procedural technical success was achieved for 1480 of 1529 patients (96.8%). All-cause mortality was 5.4% at 30 days and 16.7% at 1 year. Transseptal access was associated with lower 1-year all-cause mortality than transapical access (15.8% vs 21.7%; P = .03). Transcatheter MViV led to early, sustained, and clinically meaningful improvements in heart failure (class III/IV New York Heart Association heart failure of 87.1% at baseline vs 9.7% at 1 year). The mean (SD) mitral valve gradient at 1 year was 7 (2.89) mm Hg. CONCLUSIONS AND RELEVANCE: Transcatheter MViV using the SAPIEN 3 transcatheter heart valve is associated with high technical success, low 30-day and 1-year mortality, significant improvement of heart failure symptoms, and sustained valve performance. Transseptal MViV should be considered an option for most patients with failed surgical bioprosthetic valves and favorable anatomy.


Posted November 30th 2020

NYHA Functional Classification and Outcomes After Transcatheter Mitral Valve Repair in Heart Failure: The COAPT Trial.

Michael J. Mack M.D.

Michael J. Mack M.D.

Giustino, G., Lindenfeld, J., Abraham, W.T., Kar, S., Lim, D.S., Grayburn, P.A., Kapadia, S.R., Cohen, D.J., Kotinkaduwa, L.N., Weissman, N.J., Mack, M.J. and Stone, G.W. (2020). “NYHA Functional Classification and Outcomes After Transcatheter Mitral Valve Repair in Heart Failure: The COAPT Trial.” JACC Cardiovasc Interv 13(20): 2317-2328.

Full text of this article.

OBJECTIVES: The aim of this study was to evaluate the outcomes of MitraClip implantation versus guideline-directed medical therapy (GDMT) in patients with secondary mitral regurgitation (SMR) according to baseline functional status as assessed by the widely used New York Heart Association (NYHA) functional classification. BACKGROUND: Patients with heart failure (HF) and impaired functional status at baseline have poor prognosis. Whether the effects of transcatheter repair of secondary SMR in patients with HF are influenced by baseline functional status is unknown. METHODS: In the COAPT (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients with Functional Mitral Regurgitation) trial, patients with HF with moderate to severe or severe SMR who remained symptomatic despite maximally tolerated GDMT were randomized to MitraClip implantation versus GDMT alone. Outcomes were evaluated according to baseline functional status as assessed using the NYHA functional classification. The primary endpoint of interest was the rate of death or HF-related hospitalization (HFH) at 2 years in time-to-first-event analyses. RESULTS: Among 613 randomized patients, 240 were in NYHA functional class II (39.2%), 322 were in NYHA functional class III (52.5%), and 51 were in ambulatory NYHA functional class IV (8.3%). Rates of death or HFH were progressively higher with increasing NYHA functional class. Compared with GDMT alone, MitraClip implantation resulted in lower 2-year rates of death or HFH consistently in patients in NYHA functional class II (39.7% vs. 63.7%; hazard ratio [HR]: 0.54; 95% confidence interval [CI]: 0.37 to 0.77), NYHA functional class III (46.6% vs. 65.5%; HR: 0.60; 95% CI: 0.45 to 0.82), and NYHA functional class IV (66.7% vs. 85.2%; HR: 0.55; 95% CI: 0.28 to 1.10; p(interaction) = 0.86). Greater improvements in quality of life at 2 years were observed in patients treated with the MitraClip compared with GDMT irrespective of baseline functional status. CONCLUSIONS: The NYHA functional classification provides prognostic utility in patients with HF and moderate to severe or severe SMR. In the COAPT trial, the benefits of MitraClip implantation were consistent in patients with better or worse functional status as assessed by NYHA functional class. (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients With Functional Mitral Regurgitation [The COAPT Trial] [COAPT]; NCT01626079).


Posted November 30th 2020

Impact of Peri-Procedural Myocardial Infarction on Outcomes After Revascularization.

Michael J. Mack M.D.

Michael J. Mack M.D.

Hara, H., Serruys, P.W., Takahashi, K., Kawashima, H., Ono, M., Gao, C., Wang, R., Mohr, F.W., Holmes, D.R., Davierwala, P.M., Head, S.J., Thuijs, D., Milojevic, M., Kappetein, A.P., Garg, S., Onuma, Y. and Mack, M.J. (2020). “Impact of Peri-Procedural Myocardial Infarction on Outcomes After Revascularization.” J Am Coll Cardiol 76(14): 1622-1639.

Full text of this article.

BACKGROUND: Numerous definitions for peri-procedural myocardial infarction (PMI) following percutaneous coronary intervention (PCI) and coronary bypass grafting (CABG) surgery exist. OBJECTIVES: The purpose of this study was to investigate the PMI rates according to various definitions, their clinically relevant association with all-cause mortality at 10 years, and their impact on composite endpoints at 5 years in the SYNTAXES (Synergy between PCI with Taxus and Cardiac Surgery Extended Survival) trial. METHODS: PMI was classified as a myocardial infarction occurring within 48 h of the procedure according to definitions of the SYNTAX (TAXUS Drug-Eluting Stent Versus Coronary Artery Bypass Surgery for the Treatment of Narrowed Arteries), ISCHEMIA (International Study Of Comparative Health Effectiveness With Medical And Invasive Approaches), and EXCEL (Evaluation of XIENCE versus Coronary Artery Bypass Surgery for Effectiveness of Left Main Revascularization) trials; the Fourth Universal Definition of MI; and the Society for Cardiovascular Angiography and Interventions (SCAI). Of the 1,800 patients enrolled, 1,652 with creatine kinase and/or creatine kinase-myocardial band (CK-MB) post-procedure were included. The association between PMI and mortality was analyzed by Cox regression. RESULTS: PMI rates according to the SYNTAX and Fourth Universal Definition of MI, both of which required CK-MB elevation and electrocardiographic evidence of permanent myocardial damage, were 2.7% and 3.0%, respectively, in the PCI arm versus 2.4% and 2.1%, respectively, in the CABG arm. PMI rates according to the SCAI or EXCEL definition were higher in the PCI (5.7%) and CABG (16.5%) arms. PMIs according to the SYNTAX and Fourth Universal Definition of MI were more strongly associated with mortality than EXCEL and SCAI PMIs defined by isolated enzyme elevation when CK-MB was more than 10 times ULN. The impact of these “enzyme-driven events” on time-to-event curves and the composite endpoints was greater in the surgical cohort. PMIs after PCI were associated with 10-year mortality regardless of definition, whereas their impact on mortality after CABG was limited to 1 year. CONCLUSIONS: The rates of PMI are highly dependent on their definition, which affects time-to-event curves, composite endpoints, and their lethal prognostic relevance. (Synergy Between PCI With TAXUS and Cardiac Surgery: SYNTAX Extended Survival [SYNTAXES]; NCT03417050; SYNTAX Study: TAXUS Drug-Eluting Stent Versus Coronary Artery Bypass Surgery for the Treatment of Narrowed Arteries [SYNTAX]; NCT00114972).


Posted November 30th 2020

Structural Deterioration of Transcatheter Versus Surgical Aortic Valve Bioprostheses in the PARTNER-2 Trial.

Michael J. Mack M.D.

Michael J. Mack M.D.

Pibarot, P., Ternacle, J., Jaber, W.A., Salaun, E., Dahou, A., Asch, F.M., Weissman, N.J., Rodriguez, L., Xu, K., Annabi, M.S., Guzzetti, E., Beaudoin, J., Bernier, M., Leipsic, J., Blanke, P., Clavel, M.A., Rogers, E., Alu, M.C., Douglas, P.S., Makkar, R., Miller, D.C., Kapadia, S.R., Mack, M.J., Webb, J.G., Kodali, S.K., Smith, C.R., Herrmann, H.C., Thourani, V.H., Leon, M.B. and Hahn, R.T. (2020). “Structural Deterioration of Transcatheter Versus Surgical Aortic Valve Bioprostheses in the PARTNER-2 Trial.” J Am Coll Cardiol 76(16): 1830-1843.

Full text of this article.

BACKGROUND: It is unknown whether transcatheter valves will have similar durability as surgical bioprosthetic valves. Definitions of structural valve deterioration (SVD), based on valve related reintervention or death, underestimate the incidence of SVD. OBJECTIVES: This study sought to determine and compare the 5-year incidence of SVD, using new standardized definitions based on echocardiographic follow-up of valve function, in intermediate-risk patients with severe aortic stenosis given transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR) in the PARTNER (Placement of Aortic Transcatheter Valves) 2A trial and registry. METHODS: In the PARTNER 2A trial, patients were randomly assigned to receive either TAVR with the SAPIEN XT or SAVR, whereas in the SAPIEN 3 registry, patients were assigned to TAVR with the SAPIEN 3. The primary endpoint was the incidence of SVD, that is, the composite of SVD-related hemodynamic valve deterioration during echocardiographic follow-up and/or SVD-related bioprosthetic valve failure (BVF) at 5 years. RESULTS: Compared with SAVR, the SAPIEN-XT TAVR cohort had a significantly higher 5-year exposure adjusted incidence rates (per 100 patient-years) of SVD (1.61 ± 0.24% vs. 0.63 ± 0.16%), SVD-related BVF (0.58 ± 0.14% vs. 0.12 ± 0.07%), and all-cause (structural or nonstructural) BVF (0.81 ± 0.16% vs. 0.27 ± 0.10%) (p ≤ 0.01 for all). The 5-year rates of SVD (0.68 ± 0.18% vs. 0.60 ± 0.17%; p = 0.71), SVD-related BVF (0.29 ± 0.12% vs. 0.14 ± 0.08%; p = 0.25), and all-cause BVF (0.60 ± 0.15% vs. 0.32 ± 0.11%; p = 0.32) in SAPIEN 3 TAVR were not significantly different to a propensity score matched SAVR cohort. The 5-year rates of SVD and SVD-related BVF were significantly lower in SAPIEN 3 versus SAPIEN XT TAVR matched cohorts. CONCLUSIONS: Compared with SAVR, the second-generation SAPIEN XT balloon-expandable valve has a higher 5-year rate of SVD, whereas the third-generation SAPIEN 3 has a rate of SVD that was not different from SAVR.


Posted November 30th 2020

Baseline Functional Capacity and Transcatheter Mitral Valve Repair in Heart Failure With Secondary Mitral Regurgitation.

Michael J. Mack M.D.

Michael J. Mack M.D.

Malik, U.I., Ambrosy, A.P., Ku, I.A., Mishell, J.M., Kar, S., Lim, D.S., Whisenant, B.K., Cohen, D.J., Arnold, S.V., Kotinkaduwa, L.N., Lindenfeld, J., Abraham, W.T., Mack, M.J. and Stone, G.W. (2020). “Baseline Functional Capacity and Transcatheter Mitral Valve Repair in Heart Failure With Secondary Mitral Regurgitation.” JACC Cardiovasc Interv 13(20): 2331-2341.

Full text of this article.

OBJECTIVES: The aim of this study was to determine the prognostic utility of baseline functional status and its impact on the outcomes of transcatheter mitral valve repair (TMVr) in patients with heart failure (HF) with secondary mitral regurgitation (SMR). BACKGROUND: The COAPT (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients With Functional Mitral Regurgitation) trial demonstrated that TMVr with the MitraClip in patients with HF with moderate to severe or severe SMR improved health-related quality of life. The clinical utility of a baseline assessment of functional status for evaluating prognosis and identifying candidates likely to derive a robust benefit from TMVr has not been previously studied in patients with HF with SMR. METHODS: The COAPT study was a multicenter, randomized, controlled, parallel-group, open-label trial of TMVr with the MitraClip plus guideline-directed medical therapy (GDMT) versus GDMT alone in patients with HF, left ventricular ejection fraction 20% to 50%, and moderate to severe or severe SMR. Baseline functional status was assessed by 6-min walk distance (6MWD). RESULTS: Patients with 6MWD less than the median (240 m) were older, were more likely to be female, and had more comorbidities. After multivariate modeling, age (p = 0.005), baseline hemoglobin (p = 0.007), and New York Heart Association functional class III/IV symptoms (p < 0.0001) were independent clinical predictors of 6MWD. Patients with 6MWD <240 m versus ≥240 m had a higher unadjusted and adjusted rate of the 2-year composite of all-cause death or HF hospitalization (64.4% vs. 48.6%; adjusted hazard ratio: 1.53; 95% confidence interval: 1.19 to 1.98; p = 0.001). However, there was no interaction between baseline 6MWD and the relative effectiveness of TMVr plus GDMT versus GDMT alone with respect to the composite endpoint (p = 0.633). CONCLUSIONS: Baseline assessment of functional capacity by 6MWD was a powerful discriminator of prognosis in patients with HF with SMR. TMVr with the MitraClip provided substantial improvements in clinical outcomes for this population irrespective of baseline functional capacity.