Research Spotlight

Posted November 30th 2020

Impact of Peri-Procedural Myocardial Infarction on Outcomes After Revascularization.

Michael J. Mack M.D.

Michael J. Mack M.D.

Hara, H., Serruys, P.W., Takahashi, K., Kawashima, H., Ono, M., Gao, C., Wang, R., Mohr, F.W., Holmes, D.R., Davierwala, P.M., Head, S.J., Thuijs, D., Milojevic, M., Kappetein, A.P., Garg, S., Onuma, Y. and Mack, M.J. (2020). “Impact of Peri-Procedural Myocardial Infarction on Outcomes After Revascularization.” J Am Coll Cardiol 76(14): 1622-1639.

Full text of this article.

BACKGROUND: Numerous definitions for peri-procedural myocardial infarction (PMI) following percutaneous coronary intervention (PCI) and coronary bypass grafting (CABG) surgery exist. OBJECTIVES: The purpose of this study was to investigate the PMI rates according to various definitions, their clinically relevant association with all-cause mortality at 10 years, and their impact on composite endpoints at 5 years in the SYNTAXES (Synergy between PCI with Taxus and Cardiac Surgery Extended Survival) trial. METHODS: PMI was classified as a myocardial infarction occurring within 48 h of the procedure according to definitions of the SYNTAX (TAXUS Drug-Eluting Stent Versus Coronary Artery Bypass Surgery for the Treatment of Narrowed Arteries), ISCHEMIA (International Study Of Comparative Health Effectiveness With Medical And Invasive Approaches), and EXCEL (Evaluation of XIENCE versus Coronary Artery Bypass Surgery for Effectiveness of Left Main Revascularization) trials; the Fourth Universal Definition of MI; and the Society for Cardiovascular Angiography and Interventions (SCAI). Of the 1,800 patients enrolled, 1,652 with creatine kinase and/or creatine kinase-myocardial band (CK-MB) post-procedure were included. The association between PMI and mortality was analyzed by Cox regression. RESULTS: PMI rates according to the SYNTAX and Fourth Universal Definition of MI, both of which required CK-MB elevation and electrocardiographic evidence of permanent myocardial damage, were 2.7% and 3.0%, respectively, in the PCI arm versus 2.4% and 2.1%, respectively, in the CABG arm. PMI rates according to the SCAI or EXCEL definition were higher in the PCI (5.7%) and CABG (16.5%) arms. PMIs according to the SYNTAX and Fourth Universal Definition of MI were more strongly associated with mortality than EXCEL and SCAI PMIs defined by isolated enzyme elevation when CK-MB was more than 10 times ULN. The impact of these “enzyme-driven events” on time-to-event curves and the composite endpoints was greater in the surgical cohort. PMIs after PCI were associated with 10-year mortality regardless of definition, whereas their impact on mortality after CABG was limited to 1 year. CONCLUSIONS: The rates of PMI are highly dependent on their definition, which affects time-to-event curves, composite endpoints, and their lethal prognostic relevance. (Synergy Between PCI With TAXUS and Cardiac Surgery: SYNTAX Extended Survival [SYNTAXES]; NCT03417050; SYNTAX Study: TAXUS Drug-Eluting Stent Versus Coronary Artery Bypass Surgery for the Treatment of Narrowed Arteries [SYNTAX]; NCT00114972).


Posted November 30th 2020

Structural Deterioration of Transcatheter Versus Surgical Aortic Valve Bioprostheses in the PARTNER-2 Trial.

Michael J. Mack M.D.

Michael J. Mack M.D.

Pibarot, P., Ternacle, J., Jaber, W.A., Salaun, E., Dahou, A., Asch, F.M., Weissman, N.J., Rodriguez, L., Xu, K., Annabi, M.S., Guzzetti, E., Beaudoin, J., Bernier, M., Leipsic, J., Blanke, P., Clavel, M.A., Rogers, E., Alu, M.C., Douglas, P.S., Makkar, R., Miller, D.C., Kapadia, S.R., Mack, M.J., Webb, J.G., Kodali, S.K., Smith, C.R., Herrmann, H.C., Thourani, V.H., Leon, M.B. and Hahn, R.T. (2020). “Structural Deterioration of Transcatheter Versus Surgical Aortic Valve Bioprostheses in the PARTNER-2 Trial.” J Am Coll Cardiol 76(16): 1830-1843.

Full text of this article.

BACKGROUND: It is unknown whether transcatheter valves will have similar durability as surgical bioprosthetic valves. Definitions of structural valve deterioration (SVD), based on valve related reintervention or death, underestimate the incidence of SVD. OBJECTIVES: This study sought to determine and compare the 5-year incidence of SVD, using new standardized definitions based on echocardiographic follow-up of valve function, in intermediate-risk patients with severe aortic stenosis given transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR) in the PARTNER (Placement of Aortic Transcatheter Valves) 2A trial and registry. METHODS: In the PARTNER 2A trial, patients were randomly assigned to receive either TAVR with the SAPIEN XT or SAVR, whereas in the SAPIEN 3 registry, patients were assigned to TAVR with the SAPIEN 3. The primary endpoint was the incidence of SVD, that is, the composite of SVD-related hemodynamic valve deterioration during echocardiographic follow-up and/or SVD-related bioprosthetic valve failure (BVF) at 5 years. RESULTS: Compared with SAVR, the SAPIEN-XT TAVR cohort had a significantly higher 5-year exposure adjusted incidence rates (per 100 patient-years) of SVD (1.61 ± 0.24% vs. 0.63 ± 0.16%), SVD-related BVF (0.58 ± 0.14% vs. 0.12 ± 0.07%), and all-cause (structural or nonstructural) BVF (0.81 ± 0.16% vs. 0.27 ± 0.10%) (p ≤ 0.01 for all). The 5-year rates of SVD (0.68 ± 0.18% vs. 0.60 ± 0.17%; p = 0.71), SVD-related BVF (0.29 ± 0.12% vs. 0.14 ± 0.08%; p = 0.25), and all-cause BVF (0.60 ± 0.15% vs. 0.32 ± 0.11%; p = 0.32) in SAPIEN 3 TAVR were not significantly different to a propensity score matched SAVR cohort. The 5-year rates of SVD and SVD-related BVF were significantly lower in SAPIEN 3 versus SAPIEN XT TAVR matched cohorts. CONCLUSIONS: Compared with SAVR, the second-generation SAPIEN XT balloon-expandable valve has a higher 5-year rate of SVD, whereas the third-generation SAPIEN 3 has a rate of SVD that was not different from SAVR.


Posted November 30th 2020

Baseline Functional Capacity and Transcatheter Mitral Valve Repair in Heart Failure With Secondary Mitral Regurgitation.

Michael J. Mack M.D.

Michael J. Mack M.D.

Malik, U.I., Ambrosy, A.P., Ku, I.A., Mishell, J.M., Kar, S., Lim, D.S., Whisenant, B.K., Cohen, D.J., Arnold, S.V., Kotinkaduwa, L.N., Lindenfeld, J., Abraham, W.T., Mack, M.J. and Stone, G.W. (2020). “Baseline Functional Capacity and Transcatheter Mitral Valve Repair in Heart Failure With Secondary Mitral Regurgitation.” JACC Cardiovasc Interv 13(20): 2331-2341.

Full text of this article.

OBJECTIVES: The aim of this study was to determine the prognostic utility of baseline functional status and its impact on the outcomes of transcatheter mitral valve repair (TMVr) in patients with heart failure (HF) with secondary mitral regurgitation (SMR). BACKGROUND: The COAPT (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients With Functional Mitral Regurgitation) trial demonstrated that TMVr with the MitraClip in patients with HF with moderate to severe or severe SMR improved health-related quality of life. The clinical utility of a baseline assessment of functional status for evaluating prognosis and identifying candidates likely to derive a robust benefit from TMVr has not been previously studied in patients with HF with SMR. METHODS: The COAPT study was a multicenter, randomized, controlled, parallel-group, open-label trial of TMVr with the MitraClip plus guideline-directed medical therapy (GDMT) versus GDMT alone in patients with HF, left ventricular ejection fraction 20% to 50%, and moderate to severe or severe SMR. Baseline functional status was assessed by 6-min walk distance (6MWD). RESULTS: Patients with 6MWD less than the median (240 m) were older, were more likely to be female, and had more comorbidities. After multivariate modeling, age (p = 0.005), baseline hemoglobin (p = 0.007), and New York Heart Association functional class III/IV symptoms (p < 0.0001) were independent clinical predictors of 6MWD. Patients with 6MWD <240 m versus ≥240 m had a higher unadjusted and adjusted rate of the 2-year composite of all-cause death or HF hospitalization (64.4% vs. 48.6%; adjusted hazard ratio: 1.53; 95% confidence interval: 1.19 to 1.98; p = 0.001). However, there was no interaction between baseline 6MWD and the relative effectiveness of TMVr plus GDMT versus GDMT alone with respect to the composite endpoint (p = 0.633). CONCLUSIONS: Baseline assessment of functional capacity by 6MWD was a powerful discriminator of prognosis in patients with HF with SMR. TMVr with the MitraClip provided substantial improvements in clinical outcomes for this population irrespective of baseline functional capacity.


Posted November 30th 2020

Transcatheter Mitral Valve Repair in Patients With and Without Cardiac Resynchronization Therapy: The COAPT Trial.

Michael J. Mack M.D.

Michael J. Mack M.D.

Kosmidou, I., Lindenfeld, J., Abraham, W.T., Kar, S., Lim, D.S., Mishell, J.M., Whisenant, B.K., Kipperman, R.M., Boudoulas, K.D., Redfors, B., Shahim, B., Zhang, Z., Mack, M.J. and Stone, G.W. (2020). “Transcatheter Mitral Valve Repair in Patients With and Without Cardiac Resynchronization Therapy: The COAPT Trial.” Circ Heart Fail 13(11): e007293

Full text of this article.

BACKGROUND: In the COAPT trial (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients With Functional Mitral Regurgitation), treatment of heart failure (HF) patients with moderate-severe or severe secondary mitral regurgitation with transcatheter mitral valve repair (TMVr) using the MitraClip plus guideline-directed medical therapy (GDMT) reduced 2-year rates of HF hospitalization and all-cause mortality compared with GDMT alone. Whether the benefits of the MitraClip extend to patients with previously implanted cardiac resynchronization therapy (CRT) is unknown. We sought to examine the effect of prior CRT in patients enrolled in COAPT. METHODS: Patients (N=614) with moderate-severe or severe secondary mitral regurgitation who remained symptomatic despite maximally tolerated doses of GDMT were randomized 1:1 to the MitraClip (TMVr arm) versus GDMT only (control arm). Outcomes were assessed according to prior CRT use. RESULTS: Among 614 patients, 224 (36.5%) had prior CRT (115 and 109 randomized to TMVr and control, respectively) and 390 (63.5%) had no CRT (187 and 203 randomized to TMVr and control, respectively). Patients with CRT had similar 2-year rates of the composite of death or HF hospitalization compared with those without CRT (57.6% versus 55%, P=0.32). Death or HF hospitalization at 2 years was lower with TMVr versus control treatment in patients with prior CRT (48.6% versus 67.2%, hazard ratio, 0.60 [95% CI, 0.42-0.86]) and without CRT (42.5% versus 66.9%, hazard ratio, 0.52 [95% CI, 0.39-0.69]; adjusted P(interaction)=0.23). The effects of TMVr with the MitraClip on reducing the 2-year rates of all-cause death (adjusted P(interaction)=0.14) and HF hospitalization (adjusted P(interaction)=0.82) were also consistent in patients with and without CRT as were improvements in quality-of-life and exercise capacity. CONCLUSIONS: In the COAPT trial, TMVr with the MitraClip improved the 2-year prognosis of patients with HF and moderate-severe or severe secondary mitral regurgitation who remained symptomatic despite maximally tolerated GDMT, regardless of prior CRT implantation.


Posted November 30th 2020

Advanced Imaging and Sampling in Barrett’s Esophagus: Artificial Intelligence to the Rescue?

Vani J.A. Konda M.D.

Vani J.A. Konda M.D.

Struyvenberg, M.R., de Groof, A.J., Bergman, J.J., van der Sommen, F., de With, P.H.N., Konda, V.J.A. and Curvers, W.L. (2021). “Advanced Imaging and Sampling in Barrett’s Esophagus: Artificial Intelligence to the Rescue?” Gastrointest Endosc Clin N Am 31(1): 91-103.

Full text of this article.

Because the current Barrett’s esophagus (BE) surveillance protocol suffers from sampling error of random biopsies and a high miss-rate of early neoplastic lesions, many new endoscopic imaging and sampling techniques have been developed. None of these techniques, however, have significantly increased the diagnostic yield of BE neoplasia. In fact, these techniques have led to an increase in the amount of visible information, yet endoscopists and pathologists inevitably suffer from variations in intra- and interobserver agreement. Artificial intelligence systems have the potential to overcome these endoscopist-dependent limitations.